导线触树单相接地故障过渡电阻时变特性分析及参数影响
Time-varying characteristic analysis and parameter influence of transition resistance of tree-contact single-phase-to-ground fault
Received:July 25, 2023  Revised:August 24, 2023
DOI:10.19753/j.issn1001-1390.2025.10.011
中文关键词: 导线触树接地故障  过渡电阻  电阻变化率
英文关键词: tree-contact single-phase-to-ground fault, transition resistance, changing rate of resistance
基金项目:国网四川省电力有限公司科技项目(521997220001)
Author NameAffiliationE-mail
Ning Xin State Grid Sichuan Electric Power Research Institute 15881198955@193.com 
Zhang Hua State Grid Sichuan Electric Power Research Institute 15881198955@193.com 
Shang Hao School of electrical engineering, SIchuan University 2021223030049@stu.scu.edu.cn 
Ning Wenjun* School of electrical engineering, SIchuan University ningwj@scu.edu.cn 
Hits: 102
Download times: 25
中文摘要:
      导线触树单相接地故障(tree-contact single-phase-to-ground fault,TSF)可能点燃树木造成火灾,威胁群众生命财产安全。但TSF故障特征微弱,难以辨识,亟待深入研究其故障机理及特征。文章基于10 kV模拟线路实验平台,构造TSF进行研究。实验结果表明,TSF发展过程可以大致分为4个阶段,各阶段故障点电流波形存在不同特征,TSF的过渡电阻随故障发展逐渐减小,过渡电阻的变化率也随故障发展逐渐减小。树枝的长度、粗细和种类对TSF过渡电阻的大小和变化率均有影响。
英文摘要:
      Tree-contact single-phase-to-ground fault (TSF) may ignite trees and cause fire, threatening the life and property of people. However, the fault characteristics of TSF are weak and difficult to identify, so it is urgent to further study the fault mechanism and characteristics. In this paper, TSF is constructed based on 10 kV analog circuit experiment platform. The experimental results show that the development process of TSF can be roughly divided into four stages. Fault point current waveform has different characteristics in different stages. The transition resistance and the changing rate of transition resistance of TSF gradually decreases with the development of fault. The length, thickness and species of the tree are all able to affect the magnitude and the changing rate of the transition resistance of TSF.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd