文章摘要
PLC辐射干扰测量的外推因子研究
Research on the Extrapolation Factor for PLC Radiation Measurements
Received:September 08, 2013  Revised:September 08, 2013
DOI:
中文关键词: 电力线载波通信  电磁兼容  辐射干扰测量  外推因子
英文关键词: power line communications, electromagnetic compatibility, radiation measurement,extrapolation factor
基金项目:国家电网公司“千人计划”专项“新一代智能电力线载波通信关键技术研究”
Author NameAffiliationE-mail
LU Yang* China Electric Power Research Institute,Haidian District luyang@epri.sgcc.com.cn 
FU Wei-long Information Engineering School,Communication University of China,Chaoyang District fuweilong@cuc.edu.cn 
Hits: 2437
Download times: 733
中文摘要:
      在研究电力线载波通信(Power Line Communications,PLC)系统辐射干扰的过程中,为了比较在不同距离处获得的PLC系统辐射干扰测量结果,需要利用外推因子把不同测量距离下的辐射场强转化为标准距离下的辐射场强。本文基于赫兹偶极子与麦克斯韦方程组推导了在150 kHz-30 MHz频率等级上的电力线辐射外推因子,理论结果显示从3 m外向3 m标准测量距离转化的外推因子随频率的增大呈现出减小趋势。在此基础上,提出了适用于150 kHz-30 MHz 频率等级的PLC 辐射干扰测量方案,并在屏蔽室内进行了辐射干扰测量。分析后发现测量得到的外推因子与理论计算结果基本吻合。
英文摘要:
      In order to compare the radiation measurements in Power Line Communications (PLC) systems, the detected radiation intensity in the actual measurement distance needs to be converted to that in the normative distance based on the extrapolation factor. This paper derives the extrapolation factor for PLC radiation measurements within the frequency range 150 kHz to 30 MHz by a Hertzian dipole and using MAXWELL’s equations. The theoretical results show that the extrapolation factor from over 3 m to the normative distance 3 m will decrease with increase of frequencies. Moreover, an experimental approach for PLC radiation measurements in the frequency range 150kHz to 30MHz is proposed and performed in the shielded room. The analysis shows that the extrapolation factor derived from the measurements verifies the analytical results.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd