文章摘要
一种改进的三相电网谐波及无功检测方法
An Improved Three-phase Circuit Harmonics and Reactive Currents Detection Method
Received:January 18, 2014  Revised:July 10, 2014
DOI:
中文关键词: d-q算法  对称分量法  最小均方自适应算法  电流检测
英文关键词: d-q algorithm, symmetric-component method, LMS algorithm, currents detection
基金项目:国家自然科学基金项目(面上项目,重点项目,重大项目)
Author NameAffiliationE-mail
CaiBing* School of Electrical and Information Engineering, JiangSu University caibingzj0710@163.com 
Sun Yu-kun College of Power Engineering, Nanjing Institute of Technology  
ZhangLiang College of Power Engineering, Nanjing Institute of Technology  
Hits: 1589
Download times: 771
中文摘要:
      为了更加快速、精确地检测出三相电力系统中的谐波和无功电流,基于瞬时无功功率理论,本文在传统d-q检测算法基础上进行了改进,针对锁相环容易受到电网波动影响的缺陷,采用一种无锁相环谐波和无功电流检测方法;针对低通滤波器滤波效果与响应速度无法兼顾的缺陷,采用一种变步长LMS滤波器;结合以上两种方法的优点,得到一种无锁相环无低通滤波器的检测方法。理论分析和仿真结果验证了该方法的可行性和准确性。
英文摘要:
      In order to improve the detection speed and accuracy of circuit harmonic and reactive current in the three-phase power system, based on the instantaneous reactive power theory, this paper carried out improvement base on traditional d-q detection algorithm, used a detection method for circuit harmonic and reactive current without PLL for the problem of the phase-locked loop; used a variable step-size least mean square (LMS) adaptive filter for the low-pass filter (LPF) problem. Then combining the advantages of these two methods, we received a method without PLL and LPF. Theory analysis and simulation results illustrate feasibility and accuracy of the new method.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd