• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
后置低通滤波器对冲击负荷电能计量的影响
The Influence on the Rear Low-Pass Filter for Electric Energy Metering
Received:May 27, 2014  Revised:May 27, 2014
DOI:
中文关键词: 冲击负荷  电子式电能表  滤波器  电弧炉  电能计量
英文关键词: impact load  electronic power meter  filter  arc furnace  electric energy measurement  
基金项目:
Author NameAffiliationE-mail
PENG Hong-liang* School of Electrical Engineering, Wuhan University phl@whu.edu.cn 
LIU Kai-pei School of Electrical Engineering, Wuhan University  
CHEN Yi-huang School of Electrical Engineering, Wuhan University  
Hits: 2813
Download times: 1066
中文摘要:
      从电子式电能表有功计量的原理出发定量分析了后置低通滤波器对电能计量的影响。从理论分析结果可以得出电子式电能表后置低通滤波器对计量周期性的电压电流波形理论上没有影响,对计量冲击负荷产生的非周期性的电压电流波形将会导致计量不准确。最后以电弧炉负荷为例,建立了研究冲击负荷电能计量的仿真模型,仿真结果表明电子式电能表后置低通滤波器会加大冲击负荷电能计量误差。
英文摘要:
      The effect of rear low-pass filter on electric energy metering has been analyzed quantitatively according to the principle of active power metering. The theoretical analysis results show that the rear low-pass filter of the electric energy meter has no effect to the measurement of voltage and current waveforms periodic, while metering inaccuracy coming out for voltage and current aperiodic waveforms produced by impact load. Taking the electric arc furnace load as an example, a simulation model to study electric energy metering for the impact loads has been built. The simulation results show that the rear low-pass filter of electronic energy meter will increase electric energy metering error for the impact load.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd