• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
可改善微网孤岛模式下负荷分配的改进下垂控制
An Improved Droop Control for Improving Load Distribution in an Autonomous Microgrid
Received:May 29, 2014  Revised:May 29, 2014
DOI:
中文关键词: 微网  孤岛模式  下垂控制  负荷分配  下垂增益
英文关键词: microgrid, islanded  mode, droop  control, load  distribution, droop  gain
基金项目:
Author NameAffiliationE-mail
LIN yan Fujian Electric Power Research Institute lyepri@163.com 
WU Dan-yue Fujian Electric Power Research Institute  
LIU Jian-hua* School of Electrical Engineering and Information, Sichuan University 565173075@qq.com 
Hits: 1930
Download times: 855
中文摘要:
      针对传统下垂控制难以保证微网孤岛模式下负荷分配准确的问题,通过对功率分配特性的深入分析,得到了额定功率和线路阻抗不匹配是造成分配不准确的根本原因,在此基础上提出了一种依靠静态修正下垂增益来改善功率分配特性的方法。该方法不会改变传统下垂控制方程的形式,对系统动态特性和稳定性无显著影响,对微网运行电压的影响也较小。在Matlab/Simulink仿真平台上验证了所提改进方法的有效性。
英文摘要:
      The conventional droop control is difficult to guarantee the load power distribution accurately in the islanded mode microgrid, through in-depth analysis of the power distribution characteristics, the conclusion that the mismatch of rated power and line impedance is the root cause of inaccurate distribution is got, an improved method depend on static correct the droop gain to improve power distribution characteristics is proposed on this basis. This method does not change the equation form of the conventional droop control, and has no significant effect on the system dynamic performance and stability, the impact on the operating voltage is also lesser. The effectiveness of the improved method is verified on the Matlab/Simulink simulation platform.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd