• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
基于ICA和MI的谐波源识别研究
Study on Harmonic Source Identification Based on ICA and MI
Received:June 03, 2014  Revised:June 03, 2014
DOI:
中文关键词: 谐波源识别  独立分量分析  互信息论
英文关键词: harmonic source identification  independent component analysis  mutual information
基金项目:
Author NameAffiliationE-mail
REN Li-zhi* College of Energy and Electrical Engineering,Hohai University renlizhi23409@163.com 
MA Hong-zhong College of Energy and Electrical Engineering,Hohai University  
SONG Shu-ping College of Energy and Electrical Engineering,Hohai University  
XU Gang College of Energy and Electrical Engineering,Hohai University  
CHEN Yong Yixing Power Supply Corporation  
Hits: 2009
Download times: 866
中文摘要:
      把电力系统谐波源识别问题抽象为盲源分离问题。运用独立分量分析和互信息论,提出了一种电网多谐波源识别的新方法。独立分量分析法用于重构谐波电流,互信息论用于谐波源的定位。为证明所述方法的正确性,运用IEEE39节点建立仿真来识别多谐波源。结论证明在网络参数未知的条件下,所提出的方法能准确识别多个谐波源的位置。
英文摘要:
      The harmonic source identification problem of power system is abstracted to blind source separation. Using independent component analysis and information theory, propose a new method for power grid multi harmonic sources identification. Independent component analysis method is used to reconstruct the harmonic current while mutual information theory is used to locate the harmonic source. In order to prove exactness of the method, use the IEEE39 nodes simulation to identify multi harmonic sources. Conclusion proves that under the unknown network parameters conditions, the proposed method can accurately identify the location of the multi harmonic sources.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd