文章摘要
三相五柱式消弧线圈新调谐方法
A new tuning method of three-phase five-column arc-suppression coil
Received:June 06, 2014  Revised:June 06, 2014
DOI:
中文关键词: 电容电流,导纳关系图,阻尼率,极值法
英文关键词: capacitive current, admittance diagram, the damping rate, extreme value method
基金项目:国家自然科学基金项目(面上项目,重点项目,重大项目)
Author NameAffiliationE-mail
shaorui Huaibei Coal Mining Group Corporation Ltd Email:lhjhsr@126.com 
jinwei* Xu Zhou Runze Electrical CO.LTD  
liulei Xu Zhou Runze Electrical CO.LTD  
Hits: 1593
Download times: 818
中文摘要:
      作为调感式消弧线圈中的一种,三相五柱式消弧线圈利用可控硅实现无级调节。但其调谐原理多采用极值法,极值法在谐振点附近零序电压变化不大,极值点的寻找精度不高,电容电流的测量容易与实际值出现偏差。本文为了解决极大值点难以寻找的问题,提出了一种新的调谐方法。根据测量的零序电压相位关系和系统阻尼率不变的特点,根据调谐构造出系统的导纳关系图,利用导纳角差计算系统的电容电流,使用MATLB仿真计算和实验平台实验测量,表明该方法比极值法计算的精度更高。
英文摘要:
      Three-phase five-column arc suppression coil, as a tune arc-suppression coil, use SCR to adjust inductance steplessly. Extreme tuning principle is usually used, but zero sequence voltage changes little in the vicinity of the resonance point, It is not easy to search extreme point accurately, so large deviation occurs between the measurement of capacitive current and the actual value. A new method for tuning is proposed in this paper in order to solve the problem, According to zero sequence voltage phase relations measured and the characteristics of unchanged damping rate in the system, the admittance diagram is constructed by tuning and capacitive current can be computed through admittance angle. MATLB simulation and experiment platform measurements show that precision of this method is higher than extreme value method.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd