• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
计及不确定性和谐波畸变的分布式电源最优配置
Optimal Configuration of Distributed Generator Considering Uncertainties and Harmonic Distortion
Received:July 25, 2014  Revised:July 25, 2014
DOI:
中文关键词: 分布式电源  优化配置  谐波畸变  不确定性  区间分析
英文关键词: distributed generator  optimal configuration  harmonic distortion  uncertainty  interval analysis
基金项目:
Author NameAffiliationE-mail
LI Lan-fang Guangdong Electric Power Research Institute 13925190911@126.com 
MA Ming Guangdong Electric Power Research Institute  
LIU Zheng-fu Guangdong Electric Power Research Institute  
HAN Fei* Sichuan University hanfei_1211@163.com 
Hits: 1968
Download times: 668
中文摘要:
      针对配网中存在谐波畸变,且存在多种不确定因素的问题,提出在分布式电源(distributed generator,DG)优化配置模型中考虑谐波畸变限值,并利用区间数表示不确定因素。DG优化模型以DG成本电价、网络损耗及电压稳定性为指标,并在满足配网潮流安全性约束的基础上增加谐波畸变限值的约束,建立多目标优化模型。最后利用基于区间TOPSIS(technique for order preference by similarity to ideal solution)算法定量分析不确定因素的影响,并与非劣排序遗传算法(nondominated sorting genetic algorithm,NSGA)相结合求出DG最优配置方案。算例验证表明该方法可有效降低谐波畸变率,实现DG发电效益和供电质量的综合最优。
英文摘要:
      To solve the harmonic distortion problem and multiple uncertainties existing in distribution network, the distributed generators (DGs) optimal configuration method is proposed, with harmonic distortion taken into account and uncertainties denoted by interval numbers. The cost of electricity, the network loss and the voltage stability are taken as optimization indexes, and the harmonic distortion limit is added as a constraint based on meeting the security constraints of distribution power flow, then a multi-object optimization model is established. The method of technique for order preference by similarity to ideal solution (TOPSIS) based on interval mathematics is used to analyze uncertainties quantitatively. And the combination of it and the nondominated sorting genetic algorithm-II (NSGA-II) is used to solve the multi-objective model. The simulation results show that the optimal model can decrease the harmonic distortion effectively, and realize the integrated optimal performance of generation power benefit and power quality.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd