• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
基于可控整流的级联SVG直流侧电压平衡控制
The dc voltages balance control of the cascaded STATCOM based on controlled rectifiers
Received:September 05, 2014  Revised:September 05, 2014
DOI:
中文关键词: 静止无功补偿器  整流器  单位功率因数  电容电压平衡  级联多电平
英文关键词: static synchronous compensator  rectifier  unit power factor  voltage balance  cascaded multilevel
基金项目:
Author NameAffiliationE-mail
HU Xin* Energy and Power Engineering College,Nanjing University of Science and Technology hx0510804@163.com 
CHEN Jin-cao Energy and Power Engineering College,Nanjing University of Science and Technology  
ZHU Xiang-jing Automation College,Nanjing University of Science and Technology  
Hits: 2169
Download times: 513
中文摘要:
      针对级联多电平静止无功补偿器(STATCOM)的直流侧电容电压存在平衡性和稳定性的问题,提出采用可控整流技术对电容电压进行控制。给出了该系统数学模型的建立过程,研究了控制器的设计方法,并在SIMPLORER软件平台上完成了系统模型的搭建,仿真结果表明,整流器可以有效地补偿各个H桥中的损耗差异,使电容电压保持较好的平衡性和稳定性。在仿真结果中,还给出了逆变侧在直接电流控制和间接电流控制下不同的控制效果,比较了它们的优缺点。具有一定的实用性和可行性。
英文摘要:
      The capacitors’ voltages could be unbalanced and unstable at the dc link in the cascaded multilevel static synchronous compensator(STATCOM). A strategy that the rectifiers control the capacitors’ voltages is presented. The modelling of the system and the design process of the controllers are listed. Also the system’s model is built on the simulation software SIMPLORER .The result of the simulation shows that the rectifiers could efficiently compensate the power loss difference in the H bridges, which keeps the capacitors’ voltages in benign balance and stability. The result also gives the comparison when the inverter works under the direct current control and the indirect current control ,in which the advantages and the disadvantages are discussed. The strategy suggested is practical and feasible.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd