交叉互联电缆行波故障测距的研究
Research of Traveling Wave Based Fault Location for Cross-bonded Power Cable
Received:November 21, 2014  Revised:January 15, 2015
DOI:
中文关键词: 电缆  交叉互联  行波测距  相模变换  ATP-EMTP
英文关键词: power  cable, cross-bonded, traveling  wave based  fault location, phase-mode  transformation, ATP-EMTP
基金项目:
Author NameAffiliationE-mail
TANG Zhong Shanghai University of Electric Power tangzhong64@163.com 
YANG Jian* Shanghai University of Electric Power 1048828776@qq.com 
Hits: 1873
Download times: 655
中文摘要:
      交叉互联电缆护层的交叉互联点和直接接地点行波波阻抗不连续,行波的折反射比较复杂,行波测距时无法识别出故障点的反射波和电缆对端反射波。本文通过分析电缆各个模量参数的特性,给出了电缆故障类型的判据,提出以电流模量4作为行波测距信号的行波测距算法,有效解决了行波在交叉互联电缆上折反射复杂给行波波头识别带来的干扰问题以及第二个反向行波的判别问题。在ATP-EMTP中建立220KV电缆系统的仿真模型,仿真结果表明该测距算法可行性好,测距精度高。
英文摘要:
      As the wave impedance is significant discontinuous at the sheath cross bonding points of the cable, the reflection and refraction of traveling wave are extremely complicated, make it hard to identify the traveling wave reflection from the fault point or the end point of cable. By analyzing the characteristic of modal parameters, this paper give the criterion of fault type judgment and proposed a novel fault location scheme which using model four as fault location signal. The scheme solve the problem of wave front identify in traditional fault location methods due to the complicated reflection and refraction of traveling wave and also solve the problem of second reverse wave identification. A model of 220KV power cable system is built by ATP-EMTP, the simulation results show that the fault location scheme is feasible and has higher accuracy.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd