文章摘要
110kV环氧浇注干式变压器绝缘结构的仿真验证
Simulation Verification on Insulation Structure of 110kV Cast Resin Dry-Type Transformer
Received:April 12, 2015  Revised:September 01, 2015
DOI:
中文关键词: 环氧浇注  干式变压器  绝缘结构  电场
英文关键词: Cast resin dry-type transformer, insulation structure, electric field
基金项目:国家重点基础研究发展计划项目(973计划)(2011CB209404)。
Author NameAffiliationE-mail
Liu Chao* School of Electrical Engineering,Wuhan University lcnhalcnha@163.com 
Ruan Jiang-jun School of Electrical Engineering,Wuhan University  
Lu Huai-dong State Grid Ji'nan power supply company  
Wen Wu School of Electrical Engineering,Wuhan University  
Liao Cai-bo School of Electrical Engineering,Wuhan University  
Hits: 2228
Download times: 880
中文摘要:
      环氧浇注干式变压器相对于其他干式变压器具有很多优点,但是出于经济性的考虑,其电压等级及容量的提高受到了制约。本文对一台尚处于设计阶段的110kV环氧浇注变压器绝缘结构进行了仿真验证。首先,建立该变压器的二维电场仿真模型;其次,根据不同的连接位置分别对该二维模型进行有限元电场仿真;再次,分析在不同连接位置下空气绝缘和环氧树脂绝缘中的电场强度;最后,根据电场结果分析得知该绝缘结构能够满足工频耐压试验的要求提出了相关的结论,并对后续工作进行了展望。
英文摘要:
      Compared with the other dry-type transformer, the cast resin transformer has many advantages. But in consideration of economy, developments in the voltage level and capacity are restricted. In this paper, the authors carry out simulation verificaion on a novel insulation structure of 110kV cast resin transformer which is still in design.Firstly, 2-D model of the transformer is built up. Secondly, electric field of this model is simulated with FEM in different link positions.Thirdly, the electric field in the air insulation and epoxy insulation is analyzed. Final, the conclusion that the insulation structure could meet the demand of power-frequency voltage-withstand test is proposed according to the analysis and the following research to do is forecasted.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd