EMD及其能量变化曲线在小电流接地系统故障选线中的应用
Application of EMD and Energy Curve to Fault Line Detection in Un-effectively Grounded System
Received:April 15, 2015  Revised:June 13, 2015
DOI:
中文关键词: 经验模态分解  本征模态函数  故障选线  接地故障  零序电流
英文关键词: EMD  IMF  fault line detection  ground fault  zero-sequence current
基金项目:国家自然科学基金重点资助项目(61433004); 国家自然科学基金(51467007).教育部少数民族高级骨干人才培养基金资助项目(教民[2008]8);
Author NameAffiliationE-mail
Zhang Cuiling* Ningxia Institute of Science and Technology escrepins@163.com 
Li Yunlu School of Information Science Engineering,Northeastern University,Liaoning Shenyang  
Hits: 1853
Download times: 542
中文摘要:
      当谐振接地系统发生单相接地故障后,所有馈线零序电流的暂态信号中包含大量的特性复杂的非平稳、非线性信号,在此基础上提出一种基于经验模态分解(empirical mode decomposition,EMD)和其能量变化曲线的单相接地故障选线方法。EMD方法的优势在于其强大的适应性,能通过信号自身的变化规律来对其进行分解;而能量曲线能够比幅值更好的对故障线路和非故障线路进行鉴别。首先对各条故障线路的零序电流进行EMD处理,然后取其一阶本征模态函数(Intrinsic Mode Function,IMF)并求其能量曲线,最后综合各个零序电流的相位、幅值以及其一阶IMF能量的大小来进行故障选线。仿真与实验的结果证明了该方法有较高的可靠性与实用性。
英文摘要:
      Aiming at the characteristics of the un-effectively grounded systems that the zero-sequence current is non-stationary and nonlinear, a new fault line detection method based on empirical mode decomposition(EMD) and energy curve was proposed in this paper. The advantage of the EMD is its great adaptability, because EMD can decompose the signal according to the signal"s change regulation itself; The energy curve is better than the amplitude at the discrimination of the fault line and non-fault lines.Firstly, each of the zero-sequence current of fault lines were EMD treatment; then we can get the first-order Intrinsic Mode Function(IMF) and its energy curve; finally the fault line detection can be done by the phase of the first-order IMF and the size of the energy. The results of the simulation and experiment indicated that the method is reliable.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd