基于希尔伯特-黄变换和小波变换的500kV变电站谐振数据对比分析
A Comparison Research on HHT and WT for Harmonic Analysis of the data of a 500kV Substation
Received:May 18, 2015  Revised:November 13, 2015
DOI:
中文关键词: 电力系统  谐振  希尔伯特-黄变换  小波变换
英文关键词: electric power system  harmonic  Hilbert-Huang transform  wavelet transform
基金项目:主变谐振监测装置的研发与应用。
Author NameAffiliationE-mail
LIU Jia Mechanical and Electrical College,Hebei Agricultural University 1255653222@qq.com 
HUO Li-min* Mechanical and Electrical College,Hebei Agricultural University huolimin@126.com 
LI Ai-feng HEREFAR  
ZANG Bin Chinese Hebei north electric Co LTD Maintenance branch  
ZHANG Zeng-juan HEREFAR  
Hits: 2047
Download times: 1177
中文摘要:
      谐振数据分析是谐振实时监测装置研制和谐振抑制的基础。本文对500kV变电站实际谐振数据,采用希尔伯特-黄变换和小波变换方法进行对比分析。首先对谐振数据进行经验模态分解(EMD)得到谐波信号的本征模态函数(IMF),再对各个IMF进行希尔伯特变换,获得各个IMF分量的瞬时频率和瞬时幅度;然后选取合适的小波基对同组谐振数据进行分析;最后总结了两种检测方法的优缺点和500kV变电站实际谐振谐波成分的幅频特性。
英文摘要:
      Harmonic data analysis is the foundation of the real-time monitoring device development and the harmonic suppression. In this paper, the HHT and WT are both used to carry on the contrast analysis to the actual harmonic data of a 500kV substation. First, the intrinsic mode functions(IMF) of the harmonic data is obtained through empirical mode decomposition (EMD), then the instantaneous frequency and instantaneous amplitude of each IMF component is obtained by the Hilbert transform in each IMF; then the appropriate wavelet was selected to analyze the same group of harmonic data; the paper finally summarizes the amplitude frequency characteristics of a 500kV substation harmonic data and the advantages and disadvantages of two kinds of detection method.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd