• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
基于不同放电模型的变压器局部放电光学特性研究
Research on the Optical Properties of Transformers Partial Discharge Based on Different Discharge Models
Received:August 02, 2015  Revised:August 04, 2015
DOI:
中文关键词: 变压器  局部放电  光信号
英文关键词: oil-immersed transformer  partial discharge  Optical signal
基金项目:上海市自然科学基金(12ZR1411700)、上海市教委优青项目(ZZSDJ12003)、上海市大学生科创项目(G2-12DXSCX-048-2012)、上海研究生创新项目(A1-0225-15-005-04)
Author NameAffiliationE-mail
Huang Chao* The Electric College of Shanghai Dianji University,Shanghai hc19890@126.com 
WEI Bengang Shanghai Municipal Electric Power Company Electric Power Research Institute  
REN Xiaoming The Electric College of Shanghai Dianji University,Shanghai  
WU Haidong The Electric College of Shanghai Dianji University,Shanghai  
Hits: 1918
Download times: 694
中文摘要:
      本文基于建立的真实变压器故障模型模拟变压器内部不同放电类型,同时为捕捉局部放电时的光学效应,建立基于光学传感器的局部放电光局放检测系统。研究中通过外施电压对沿面放电和悬浮放电缺陷模型进行加压产生局部放电信号,研究结果表明:局部放电的光学信号能够有效反应变压器内部局部放电的产生和发展过程。放电图谱中放电点的密集度,可直观评估放电的强烈程度。当放电趋于稳定时,沿面放电点的光学放电信号相位主要分布在60°~150°和240°~330°之间,悬浮放电点相位主要集中在260°~320°之间,根据光局放信号的相位特性,可以明确区分变压器内部的沿面放电和悬浮放电现象,为变压器光局放检测技术的应用奠定了基础。
英文摘要:
      In this paper, the different types of discharge in transformer was simulated based on the establishment of the real transformer fault model. The optical partial discharge detection system was established based on optical sensors which was capture partial discharge accompanied by optical effects. In this research, surface discharge and suspended discharge defect model was pressurized to generate partial discharge signal. The results showed that: OPDS is able to detect the emergence and development of transformer internal partial discharge, it is able to assess discharge level also. When the discharge phenomenon stabilized, OPDS detects the phase of surface discharge mainly between 60°~150°and 240°~330°, the phase of suspended discharge mainly between 260°~320°. according to the phase characteristic of discharge pattern, the creeping discharge and suspended discharge phenomenon of transformer can be distinguished. It laid the foundation for the application of transformer optical partial discharge detection technology.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd