• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
基于环保综合评价的电网节能环保调度研究*
Researches on Grid dispatching of energy saving and environmental protection based on environmental comprehensive evaluation
Received:October 09, 2015  Revised:December 08, 2015
DOI:
中文关键词: 节能环保调度  热力系统  焓熵流量模型  
英文关键词: dispatching  of energy  saving and  environmental protection, thermodynamic  system , enthalpy  entropy flow  model embedded  system
基金项目:
Author NameAffiliationE-mail
liang xiao* School of Electrical Engineering and Automation, Hefei University of Technology liangx0418@ah.sgcc.com.cn 
Wang Jianping School of Electrical Engineering and Automation, Hefei University of Technology 13905512289@139.com 
Ke Yuyang Department of Computer Science and Technology, University of Science and Technology of China 13696522704@139.com 
Xiong Yan Department of Computer Science and Technology, University of Science and Technology of China yxiong@ustc.edu.cn 
Hits: 1575
Download times: 589
中文摘要:
      本文提出一种基于环保综合评价以解决电网节能环保调度问题,节能环保综合值采用以焓-熵-流量三维热力状态模型表征机组系统的热力循环效率,将其整合为发电煤耗、节能潜力、污染物排放量和回水温度偏差四种因素并赋予权值计算,通过经典进化规划迭代得到电网节能环保调度的最优机组出力分配方案,最后通过合肥电厂#5机组实例表明在电网安全运行基础上,进一步发展节能、环保友好型调度模式的可行性。
英文摘要:
      In this paper, a novel environmental comprehensive evaluation is proposed to solve the problems of Grid energy saving and environmental protection dispatching. The comprehensive value adopts the enthalpy entropy flow model which used to represent the thermodynamic cycle of the power generator. It is integrated four factors of coal consumption, energy saving potential, quantity of pollutant emissions and back water temperature, and then assigned with different weights. The best output scheduling scheme at the station of energy saving and environmental protection dispatching model is obtained by the classical evolutionary programming. Subsequently, the example of fifth unit of Hefei power plant analysis shows the possibility of developing the energy-saving, environmental friendly scheduling model based on grid security and reliability.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd