文章摘要
基于谐波畸变功率的谐波源定位研究
A Method for the Detection of Harmonic Sources based on Harmonic Distortion Power
Received:March 01, 2016  Revised:March 01, 2016
DOI:
中文关键词: 谐波源定位  畸变功率  功率定义  电能质量
英文关键词: detection  of harmonic  sources, distortion  power, power  definitions, power  quality
基金项目:
Author NameAffiliationE-mail
Bai Zhixuan College of Electrical Engineering and Information Technology,Sichuan University baizhixuan1993@163.com 
Xiao Xianyong College of Electrical Engineering and Information Technology,Sichuan University 419473831@qq.com 
Zhang Yi State Grid Fujian Electric Power Research Institute zhangyifuzhou@163.com 
Wang Ying* College of Electrical Engineering and Information Technology,Sichuan University wyscu1981@163.com 
Chen Feiyu College of Electrical Engineering and Information Technology,Sichuan University 492153802@qq.com 
Hits: 1790
Download times: 816
中文摘要:
      供电网公共连接点处主谐波源的定位,是对谐波污染采取合理抑制措施的重要前提。本文从非正弦条件下功率的分解方法出发,提出一种基于谐波畸变功率的主谐波源定位新方法,实现了适用于IEEE Std. 1459-2010标准的主谐波源定位。通过比较同一系统供电线性与非线性负荷情况下视在功率分量与瞬时功率分量的对应关系,证明了谐波畸变功率对于主谐波源定位的有效性。多种情况下的仿真分析和实侧验证结果证明了本文方法的正确性和合理性。
英文摘要:
      The detection of harmonic sources on the point of common coupling (PCC) is the important premise of responsibility proration and harmonic elimination. In this paper,a method of nonlinear load detection based on harmonic distortion power is proposed, which is applicable for the IEEE Std. 1459-2010 standard. By comparing the corresponding relationship between the instantaneous power components and apparent power components of linear and nonlinear load cases, the effectiveness of the proposed method is proved. Multiple cases of simulation analysis and measurement results prove the validity and rationality of this method.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd