• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
基于故障电流分布因子的单端故障定位方法
Single terminal fault location method based on fault current distribution factor
Received:February 19, 2017  Revised:February 19, 2017
DOI:
中文关键词: 电力电缆  故障定位  单端  故障电流分布因子  加权系数
英文关键词: power  cable, fault  location, single  terminal, fault  current distribution  factor, weighting  coefficient
基金项目:国家自然科学基金(61672032);安徽省科技攻关计划项目(1604A070216)
Author NameAffiliationE-mail
Cheng Zhiyou Power Quality Engineering Research Center,Ministry of Education czy@ahu.edu.cn 
Li Xiaojing* School of Electronics and Information Engineering, Anhui University lixiaojing0007@126.com 
Tang Mingjin School of Electronics and Information Engineering, Anhui University 1657769590@qq.com 
Xia Shuang School of Electronics and Information Engineering, Anhui University 1090526719@qq.com 
Hits: 1563
Download times: 844
中文摘要:
      为了实现电力电缆的精确定位,提出了一种基于故障电流分布因子的单端故障定位方法。该方法首先根据Kirchhoff电压定理对电力系统等效模型建立表达式,然后检测线路单端三相电压、电流的正序、负序以及零序分量,接着引入故障电流分布因子,用故障类型的加权系数以及故障电流增量值替代故障电流,建立故障定位函数,最后检测出故障距离。仿真实验表明该方法鲁棒性强且具有较高的精确性。
英文摘要:
      In order to achieve precise positioning of power cable, this paper proposed a single terminal fault location method based on the fault current distribution factor. According to the Kirchhoff theorem of voltage, the method establishes expression on power system equivalent model. Then positive sequence, negative sequence and zero sequence components of voltage and current from one end of the line are detected. This method introduces the fault current distribution factor, replaces the fault current with weighting coefficient of the fault type and increment value of fault current, establishes the fault location function, finally detects the fault distance. Simulation results show that the proposed method has strong robustness and high accuracy.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd