文章摘要
极坐标图像法用于检测变压器绕组的微小辐向变形故障
Detecting transformer winding minor radial deformation fault by polar image
Received:February 23, 2017  Revised:February 23, 2017
DOI:
中文关键词: 变压器  绕组变形  频率响应分析法  极坐标图像
英文关键词: transformer  winding deformation  frequency response analysis  polar image
基金项目:国家自然科学基金
Author NameAffiliationE-mail
Song Huixin State Grid Jibei Electric Power Company Limited Skills Training Center,Hebei Baoding 071000 songhuixin001@gmail.com 
Zhang Yihua State Grid Jibei Electric Power Company Limited Skills Training Center,Hebei Baoding 071000 zhangyihua@126.com 
Li Haoran* State Grid Jibei Electric Power Company Limited Skills Training Center,Hebei Baoding 071000 lihaoran001@gmail.com 
Wang Dongmei State Grid Jibei Electric Power Company Limited Skills Training Center,Hebei Baoding 071000 wangdongmei@126.com 
Hits: 2002
Download times: 903
中文摘要:
      频率响应分析法一直以来被认为是诊断电力变压器绕组变形故障最具潜力的方式,然而,现有频率响应分析法大多仅利用频率响应的幅值信息,而忽略了其相位变化的特性,针对某些故障类型,例如绕组的微小辐向变形故障,仅利用幅值信息的方法,故障诊断的灵敏度并不高。因此,本文提出一种新的极坐标图像法,利用频率响应构造极坐标图像,进而辅助诊断绕组变形故障。通过开展绕组等效电路模型的算例分析,结论证实在传统频率响应分析法不能反映绕组微小辐向变形故障时,本文提出的方法可能更有效地检测出绕组故障,极坐标图像法具有更高的诊断灵敏度。
英文摘要:
      Frequency response analysis is always considered to be a method with most prospect to diagnose power transformer winding deformation fault, however, most existing frequency response analysis just uses the amplitude information of frequency response, and ignores the characteristic of phase variation, the sensitivity of diagnosing fault is not high enough. Thus, this paper proposes a new polar image method, the frequency response is used to construct polar image, which assists to diagnose winding deformation fault. A case study of winding equivalent electrical model is carried out, the result demonstrates that when the normal frequency response analysis can"t reflect the winding minor radial deformation fault, the method proposed in this paper may detect winding fault more effectively, the polar image method has higher sensitivity of diagnosis.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd