• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
LCL型三相光伏并网逆变器新型控制策略研究
New control strategy for three-phase PV grid-connectedinverter with LCL filter
Received:April 28, 2017  Revised:April 28, 2017
DOI:
中文关键词: 并网逆变器  LCL滤波器  陷波器  重复控制  准比例谐振控制
英文关键词: grid-connected inverter  LCL filter  notch filter  repetitive control  quasi proportional resonance control
基金项目:国家自然科学基金项目( 重点项目);中国铁路总公司科技研究开发计划项目
Author NameAffiliationE-mail
Wang Jinqiang* School of Automation and Electrical Engineering,Lanzhou Jiaotong University 1642339331@qq.com 
Wang Sihua School of Automation and Electrical Engineering,Lanzhou Jiaotong University 1399228418@qq.com 
Hits: 2941
Download times: 1739
中文摘要:
      针对LCL滤波型光伏并网逆变器是高阶多变量控制系统,传统并网电流单一控制方法,不能确保系统稳定性良好的同时又较的抑制电网电压中的各次谐波,提出了一种基于LCL型并网逆变器的新型复合电流控制技术。为了抑制LCL滤波器的固有谐振尖峰,通过在电流环中增加陷波器的方法实现了LCL滤波器的有源阻尼,提高系统稳定性的同时又不需要额外增加传感器;并网电流调节器将重复控制(RC)和准比例谐振控制(QPR)有机结合,用来改善并网逆变器的输出电流质量,降低本地非线性负载扰动和电网电压波动对并网电流造成的影响,实现对基频信号的无静差跟踪控制和单位功率因数并网。通过Matlab/Simulink仿真测试,验证了陷波器有源阻尼及重复准PR控制策略的正确性和有效性。
英文摘要:
      For LCL filter type photovoltaic grid-connected inverter is a high-order multivariable control system, the traditional parallel current control method, can not ensure that the system stability at the same time more than the suppression of the grid voltage in the harmonics, put forward a New Compound Current Control Technology Based on LCL - type Grid - connected Inverter. In order to suppress the inherent resonant spikes of the LCL filter, the active damping of the LCL filter is achieved by adding a notch filter in the current loop to improve the stability of the system without the need for additional sensors. The grid current regulator will (RC) and quasi-proportional resonance control (QPR) are used to improve the output current quality of the grid-connected inverter and reduce the influence of the local nonlinear load disturbance and the grid voltage fluctuation on the grid current. The frequency signal has no static tracking control and the unit power factor is connected. The correctness and validity of the active damping and repetitive quasi - PR control strategy of the notch are verified by Matlab / Simulink simulation test.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd