• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
充电桩网侧谐波补偿分析
Analysis of Harmonic Injection in Charge Side of Charging
Received:July 15, 2017  Revised:July 15, 2017
DOI:
中文关键词: 充电桩  平均电流控制策略  APFC电路  三次谐波补偿策略
英文关键词: Charging station  average current control strategy  Active Power Factor Correction circuit  third harmonic injection method
基金项目:
Author NameAffiliationE-mail
WU Fuzhuan Zhongyuan University of Technology 940825353@qq.com 
ZHU Jing* School of Electronic Information Zhongyuan University of Technology 940825353@qq.com 
CHEN Peng School of Electronic Information Zhongyuan University of Technology 2498665568@qq.com 
JI Zhigang ZHAI Rui School of Electronic Information Zhongyuan University of Technology 2859378292@qq.com 
Hits: 1516
Download times: 520
中文摘要:
      针对由电动汽车充电桩中非线性装置产生谐波电流等引起的电能质量问题,阐述了APFC校正下由于传统的平均电流控制策略会使网侧电流含有低次谐波分量,导致输入电流仍存在较大失真,使系统的功率因数难以进一步提高。在此基础上,分析了充电桩中谐波产生的机理,提出了在指令电流中加入三次谐波补偿进一步对谐波抑制,并从原理上分析了其可行性与有效性。最后通过MATLAB/Simulink仿真并搭建硬件平台,仿真和实验结果表明:采用该策略进一步提高了电能质量与网侧的功率因数,具有较好实用性。
英文摘要:
      In order to solve the problem of power quality caused a harmonic current generated by a non-linear device contained in an electric vehicle chargers, it is described that the traditional current control strategy under the APFC, it will make the network side current contain low harmonic components, resulting in a large distortion of the input current, making it difficult to further improve the power factor of the system. On this basis, the mechanism of the harmonic generation in the charging station is analyzed, it is proposed to add third harmonic compensation to reduce harmonic, and to analyze the feasibility and effectiveness of the principle. Finally, MATLAB/Simulink was used to simulate the system. The results show that this method can improve the power quality and power factor of the network side, and have good practicability.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd