变电站接地网电磁诊断法的试验研究
Experimental Studies on Substation Grounding Grid Fault Diagnosis Using Electrical & Magnetic Diagnosis Method
Received:July 26, 2017  Revised:July 26, 2017
DOI:
中文关键词: 接地网  地表电位  磁感应强度  故障诊断
英文关键词: grounding  grid, surface  potential, magnetic  induction intensity, fault  diagnosis
基金项目:
Author NameAffiliationE-mail
Shi Hui Fengxian Power supply branch company,Shanghai Municipal Electric Power Company 781720719@qq.com 
Wang Fenghua Key Laboratory of Control of Power Transmission and Conversion,Ministry of Education,Shanghai Jiao Tong University fhwang7723@sjtu.edu.cn 
Hu Xuming* Key Laboratory of Control of Power Transmission and Conversion,Ministry of Education,Shanghai Jiao Tong University 1960731125@qq.com 
Mao Xiaoliang Fengxian Power supply branch company,Shanghai Municipal Electric Power Company 631850834@qq.com 
Lv Peipei Fengxian Power supply branch company,Shanghai Municipal Electric Power Company 15021979618@163.com 
Meng Qibin Fengxian Power supply branch company,Shanghai Municipal Electric Power Company 513318886@qq.com 
Hits: 1669
Download times: 567
中文摘要:
      为进一步提高变电站接地网故障诊断的准确性,本文以某实际35kV变电站接地网为研究对象,通过模拟接地网导体腐蚀、断裂、虚焊等典型故障,对接地网正常与典型故障下的地表电位和磁感应强度进行了测试分析。试验结果表明:接地网导体出现不同故障类型时,地表电位和磁感应强度呈现出不同的变化规律,综合分析接地网的地表电位和磁感应强度可较为准确地实现变电站接地网故障诊断及故障类型识别。接地网存在混合故障时,故障导体地表电位和磁感应强度变化规律与单一故障的情形类似,但变化幅度更大。研究结果可为变电站接地网的故障诊断提供重要依据。
英文摘要:
      To further increase the accuracy of fault diagnosis of substation grounding grids, a 35kV substation is studied to measure the surface potential and magnetic induction intensity under normal condition and typical faults, where the fault of corrosion, broken and incomplete weld are simulated. The test results have shown that, the surface potential and magnetic induction intensity of grounding grid are changed differently under different fault circumstances. According to the comprehensive analysis of the variations of surface potential and magnetic induction intensity, the fault and its type can be identified accurately. For the hybrid fault in grounding grid, the variations of surface potential and magnetic induction intensity are similar to the single fault with larger variation degree. This result may provide important basis for future substation grounding grid fault diagnosis.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd