• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
基于交错控制的三电平升压型DC/DC光伏控制器研究
Research on Three-Level Boost-Type DC/DC photovoltatic controller based on interleaved control
Received:December 15, 2017  Revised:December 15, 2017
DOI:
中文关键词: Boost三电平  交错控制  均压  电压应力
英文关键词: Boost-TL, interleaved control, balancing  voltage, voltage stress
基金项目:国家重点研发计划(2017YFB0903205);广东省公益研究与能力建设专项基金(2015A010106018);广东省教育厅优秀青年教师项目(YQ2015156)。
Author NameAffiliationE-mail
Zhang Zhi College of Electronic Engineering,Dongguan University of Technology zhangz@dgut.edu.cn 
Zhou Hao* College of Electronic Engineering,Dongguan University of Technology zhouhao_827@163.com 
Hits: 1736
Download times: 636
中文摘要:
      介绍了一种应用于非隔离光伏并网系统前级DC/DC升压变换器及其控制方法。该变换器采用Boost三电平(Boost Three-level, Boost-TL)拓扑结构,分析了其工作原理,并建立了数学模型。通过采用将两个开关管移相180°的交错控制策略,有效地减小电感电流和输出电压的纹波。同时,通过调整开关管的导通时间解决了输出分压电容不均压的问题。该变换器能减少了开关损耗和二极管反向恢复损耗,降低功率器件的电压应力,减小变换器的体积。最后,搭建了23kW的实验平台,通过实验验证了所提控制方法的正确性和有效性。
英文摘要:
      A non-isolated photovoltatic grid-connected system DC/DC boost converter and control method is introduced. The Boost-TL topology is adopted in this converter. The working principle of Boost-TL converter is analyzed and the mathematical mode is built. In order to reduce the ripple of the inductor current and the output voltage, the interleaved control scheme is proposed by using two switches with phase shift of 180°. Simultaneously, the balancing voltage of capacitor can be achieved by control the conducting times of switching tube. The converter could reduce the volume of converters, lower of the voltage stress of switching device, reduce the diode reverse recovery loss and switching loss. Finally, a 23 kW prototype is designed for the whole system. The validity of the presented control method is verified by experiment.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd