• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
基于调感谐振的GIL出线互感器误差校验方法研究
Study on the error test based on adjustable reactor resonancein GIL voltage transformers
Received:December 17, 2017  Revised:December 17, 2017
DOI:
中文关键词: GIL出线互感器误差校验  可调电抗器  相对失谐度  电压增益
英文关键词: the error test in GIL electromagnetic voltage transformers  adjustable reactor  relative detuning  voltage gain
基金项目:
Author NameAffiliationE-mail
Wang Lei* Yunnan Electric Power Test Research Institute Group CO.,LTD 121927052@qq.com 
Shi Susu Yunnan Electric Power Test Research Institute Group CO.,LTD 573708741@qq.com 
Hits: 1363
Download times: 578
中文摘要:
      在气体绝缘金属封闭输电线路(GIL)中的电磁式电压互感器误差校验中,谐振电源系统的选配、组合是比较关键的问题。本文介绍了使用组合可调电抗器解决长距离GIL升压的电源系统,分析了该系统的数学模型,提出了工频谐振下相对失谐度的概念,并对制约电压增益的因素进行了分析。提出使用二次压降测试仪进行误差校验,给出了重点参数的测量方法及试验步骤。最后,以澜沧江糯扎渡水电站GIL出线互感器误差现场检测试验为例,进一步验证了该方法解决长距离GIL中电磁式电压互感器误差校验的可行性和有效性。
英文摘要:
      In the error check of electromagnetic potential transformer in gas insulated metal enclosed transmission line (GIL), the selection and combination of resonant power system are key problems. Consequently, this paper introduced the use of combined adjustable reactor to solve the voltage boosting in GIL, and analyzed the mathematical model of the system. The concept of relative detuning at power frequency resonance was presented. the factors which restricted the voltage gain were also analyzed. In addition, the use of secondary voltage drop tester for error checking was proposed. The key parameters measurement and test steps were given. Finally, taking the error test in GIL electromagnetic voltage transformers of Nuozhadu hydropower station as an example, experiment results have been given to verify theSfeasibility and validitySof this method
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd