基于DOST能量相似度的有源配电网故障区间定位方法
A Fault Section Location Method for Active Distribution Network Based on Discrete Orthogonal S-transform and Energy Similarity
Received:December 22, 2017  Revised:February 23, 2018
DOI:
中文关键词: 有源配电网  故障区间定位  离散正交S变换  能量相似度
英文关键词: active  distribution network, fault  section location, discrete  orthogonal S-transform, energy  similarity
基金项目:
Author NameAffiliationE-mail
Li Weiguo School of Electrical Engineering,Northeast Electric Power University 1677493048@qq.com 
Wang Xuguang* School of Electrical Engineering,Northeast Electric Power University 839042905@qq.com 
Lu Guangqi School of Electrical Engineering,Northeast Electric Power University luguangqi_neepu@sina.cn 
Xu Wenwen School of Electrical Engineering,Northeast Electric Power University 1151259489@qq.com 
Hits: 1705
Download times: 712
中文摘要:
      有源配电网小电流接地系统发生单相接地短路时,通过理论分析得出单个DG接入配电网并不影响零序电流大小的结论,由此提出一种基于离散正交S变换(DOST)暂态零序电流能量相似度的故障定位方法。首先对线路上检测设备上传的暂态零序电流信号进行离散正交S变换,然后利用得到的时频矩阵中的元素计算线路区间两端检测点的能量相似度,能量相似度小于设定的阈值即为故障区间。Matlab/Simulink仿真结果表明该方法准确有效,适用于有源配电网的故障区间定位。
英文摘要:
      When the single-phase to ground short-circuit occurs in the small-current grounding system of the active distribution network, through the theoretical analysis of single DG access to distribution network does not affect the zero sequence current conclusion, so a discrete orthogonal S-Transform (DOST) Fault location method of zero sequence current energy similarity was proposed. Firstly, discrete orthogonal S transform is applied to the transient zero sequence current signal uploaded by the detection equipment on the line, and then the energy similarity of detection points at both ends of the line section is calculated by using the data in the time-frequency matrix obtained, the energy similarity is less than the setting The threshold is the fault interval. The simulation results of Matlab / Simulink show that the method is accurate and effective and can be applied to the fault zone location of active distribution network.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd