• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
基于改进S变换的电压骤降自适应检测方法
Adaptive Detection Method for Voltage Sags with improved S-Transform
Received:December 30, 2017  Revised:December 30, 2017
DOI:
中文关键词: 电压骤降  改进S变换  分段  自适应  抗噪声
英文关键词: Voltage sag  modified S-transform(MST)  piecewise  self-adaptation  resistance to noise
基金项目:
Author NameAffiliationE-mail
wuyan* College of Electrical and Information Engineering, HunanUniversity wy_yanwu@126.com 
lijianmin college of electrical and information engineering,Hunan University ljmdzyx@163.com 
Hits: 1459
Download times: 574
中文摘要:
      由于传统S变换(S-Transform,ST)在检测电压骤降问题是存在时频分辨率不高,计算量大的问题,本文在深入研究传统S变换(modified S-Transform,MST),给出了一种基于改进S变换的电压骤降自适应检测方法,可以准确、快速地实现电压骤降参数的准确提取。本文首先给出MST中调节因子的取值依据并用实验分析法给出调节因子的取值范围;而后依据调节因子的取值分布情况,提出分段的调节因子;最后基于调节因子取值函数,建立自适应检测方法。本文在MATLAB上对本文算法进行仿真,能够准确的检测出电压骤降参数,且抑制噪声和谐波影响的效果好。实际构建的硬件测试平台验证了本文算法的正确性和可行性。
英文摘要:
      Since the low time-frquency resolation and heavy computation of S-transform when comes to detecting voltage sags,the modified S-transforn(MST) algorithm was established.Voltage sag parameters are obtained with MST in a higher resolation and speed.Firstly,the standard of adjusting factors in MST are given, and the values of adjusting factors are given by experimental analysis;Secondly,according to the distribution of the adjustment factor, the adjusting factor of piecewise is proposed.Finally,the adaptive detection method is established based on the function of adjusting factor.The simulation and test results show that the proposed method provids results with higher accurcy in time-frquency anaysis,and is appropriate for accuate and rapid detection of voltage sags.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd