• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
配电网单相接地故障残余电流转移消弧方法
Arc-suppression Method Based on Transferring the Residual Current of Single Phase Grounding Fault in Distribution Network
Received:April 23, 2018  Revised:April 23, 2018
DOI:10.19753/j.issn1001-1390.2019.011.004
中文关键词: 消弧  消弧线圈  残余电流转移消弧  中性点非有效接地
英文关键词: arc-suppression, arc  suppression coil, arc-suppression  method based  on transferring  the residual  current, non-effectively  grounded neutral
基金项目:
Author NameAffiliationE-mail
Fan Songhai State Grid Sichuan Electric Power Research Institute 879238566@qq.com 
Chen Kunyi* Sichuan university ky0304528@163.com 
Xiao Xianyong Sichuan university xiaoxianyon@163.com 
Liu Xiaojiang State Grid Sichuan Electric Power Research Institute 13408548341@163.com 
Hits: 1233
Download times: 501
中文摘要:
      根据消弧线圈和故障转移灭弧装置的优缺点,提出了一种残余电流转移的消弧方法。该方法首先利用消弧线圈将故障点电流补偿到较小数值,再投入故障转移装置转移故障点的残余电流,使电弧可靠熄灭。为了避免转移装置错误投入带来负面影响,采用两级开关结构,并用限流电阻对第一级合闸电流进行限制。通过检测限流电阻的电压或电流,可实现转移装置投入正确性以及电弧是否熄灭的判别,为故障转移装置的投退提供了可靠依据。仿真结果表明,该方法能够解决消弧线圈残流过大的问题,同时也能够避免故障转移装置错误投入带来的风险。
英文摘要:
      According to the merits and drawbacks of the arc-suppression coil and the fault transfer device, an arc suppression method based on transferring residual current is proposed. The fault point current is compensated to a smaller value by arc suppression coil, and then the residual current of the fault point is transferred by the fault transfer device, so that the arc is reliably extinguished. In order to reduce the negative impact of the false action of the transfer device, a two-stage switch structure is adopted and the current-limiting resistor is used to limit the current of the first stage. By detecting the voltage or current of the current-limiting resistor, it can distinguish the correctness of the transfer device action and whether the arc is extinguished, which provides a reliable basis for the control of the fault transfer device. The simulation results show that this method can reduced the residual current of fault point and can also avoid the risk of false action.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd