红外技术在避雷器绝缘缺陷检测中的应用
The application of infrared diagnosis in detection of lightning arrester insulation defects
Received:August 06, 2018  Revised:August 06, 2018
DOI:10.19753/j.issn1001-1390.2019.020.015
中文关键词: 金属氧化物避雷器 红外检测 绝缘受潮 发热特征
英文关键词: Metal oxide arrester(MOA)  infrared detection  insulation dampness  thermal character  
基金项目:
Author NameAffiliationE-mail
LI Yanpeng* Electric Power Research Institute of SEPC.Taiyuan,Shanxi.030001 liyanpeng1982@163.com 
Hits: 1635
Download times: 582
中文摘要:
      金属氧化物避雷器是电力设备过电压防护的重要元件,其运行状态不仅关系到自身的安全,还会给被保护设备带来影响,甚至引发电网接地故障。红外检测作为一种带电检测手段,能及时发现运行避雷器的潜在缺陷,评价避雷器是否能继续带电运行,避免缺陷扩大为电力事故。本文以红外检测发现500kV避雷器受潮缺陷为例,分析了避雷器绝缘受潮的发热特征,并通过解体分析,总结了避雷器受潮的原因及绝缘劣化规律,同时证明了红外诊断发现避雷器绝缘缺陷的及时性和准确性。
英文摘要:
      Metal oxide arrester(MOA)is an important overvoltage protection component for power equipment. Its operating state not only relates to its own safety, but also affects the protected equipment, which even leads to ground faults in the power grid. Infrared detection, as a means of live detecting of electrical equipment, can detect the arrester potential defects under operating voltage in time. It is important to check whether MOA can continue to run on the service voltage, and avoid the expansion of defects into electricity accidents. In this paper, the infrared detection of 500kV MOA was taken as an example to analyze the thermal characteristics of the insulation damp arrester. Through the disintegration analysis of MOA, the reasons for the dampening of the arrester and the principle of insulation degradation were analyzed. At the same time, the timeliness and accuracy of the infrared diagnosis to detect MOA insulation defects were proved.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd