• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
单相非隔离光伏并网逆变器拓扑推演与分析
Analysis on Topology Evolution of Single-phase Transformerless Photovoltaic Grid-connected Inverter
Received:August 13, 2018  Revised:August 13, 2018
DOI:10.19753/j.issn1001-1390.2019.020.008
中文关键词: 光伏发电  非隔离  并网逆变器  漏电流  拓扑推演
英文关键词: photovoltaic  power generation, transformerless, grid-connected  inverters, leakage  current, topological  derivation
基金项目:
Author NameAffiliationE-mail
LIAO Zhiling* School of Electrical and Information Engineering,Jiangsu University liaozhiling@ujs.edu.cn 
CAO Chenchen School of Electrical and Information Engineering,Jiangsu University 2211707023@stmail.ujs.edu.cn 
Hits: 1176
Download times: 579
中文摘要:
      针对单相非隔离光伏并网逆变器具有的漏电流问题,对单相非隔离半桥型和全桥型两大类拓扑进行拓扑演化推导,建立了一个桥式拓扑演化网络,研究分析了单相非隔离光伏并网逆变器拓扑的特点,明确了拓扑之间的相互联系,总结出各种桥式拓扑之间的演化规律。并利用总结出的演化规律推导出一种新型拓扑,进一步证明了所提出的演化规律。最后通过PSIM仿真软件进行验证,证明了所提出新型拓扑所具有的漏电流抑制功能的有效性和演化规律的正确性。
英文摘要:
      For the problem of the leakage current of single-phase transformerless photovoltaic grid-connected inverters, the topology evolution of the transformerless half-bridge type and full-bridge type is derived and a bridge-type topology evolution network is established. The topology characteristics of single-phase transformerless photovoltaic grid-connected inverter are analyzed. This paper presents some of the single-phase transformerless photovoltaic grid-connected inverter topology and discusses the evolution rules among various topologies to clarify the interrelationship between topologies. A new topology is deduced by using the evolution rules to further prove it. Finally, the validity of the leakage current suppression function of the proposed new topology and correctness of the evolution rules are verified by PSIM.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd