• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
LCL型并网逆变器的新型单电流反馈控制方案
New Single Current Feedback Control Scheme for Grid-Connected Inverter With LCL Filters
Received:September 01, 2018  Revised:September 20, 2018
DOI:10.19753/j.issn1001-1390.2020.02.021
中文关键词: 并网逆变器  有源阻尼  LCL  进网电流全前馈  高增益
英文关键词: grid-connected inverter, active damping, LCL, full feedforward of grid side current, high gain
基金项目:
Author NameAffiliationE-mail
Liao Zhiling* School of Electrical and Information Engineering,Jiangsu University liaozhiling@ujs.edu.cn 
Xu Changbo School of Electrical and Information Engineering,Jiangsu University 18352861189@163.com 
Cao Chenchen School of Electrical and Information Engineering,Jiangsu University 2211707023@stmail.ujs.edu.cn 
Hits: 1941
Download times: 522
中文摘要:
      本文基于有源阻尼控制机理特性,提出一种应用于LCL型并网逆变器的新型单电流闭环反馈控制策略。该控制策略将有源阻尼与谐振控制特性相结合,通过对进网电流全前馈控制,有效抑制谐振尖峰且实现基波频率处高增益。该控制策略不引入额外的传感器,结构简单、成本低、可靠性高。推导了该控制策略下系统传递函数,并给出其实现方法。建立MATLAB/Simulink仿真模型,验证所提控制策略的可行性与有效性。
英文摘要:
      Based on the characteristics of active damping control mechanism, a new single current closed-loop feedback control strategy for LCL grid-connected inverters is proposed in this paper. The control strategy combines active damping and resonance control. Through full feedforward of the grid side current, the resonance peak is effectively suppressed and the high gain at the fundamental frequency is realized. The control strategy contains no added additional sensors, which is simple in structure, low in cost and high in reliability. The system transfer function with the control strategy is derived and its implementation method is given. A MATLAB/Simulink simulation model is established to verify the feasibility and effectiveness of the proposed control strategy.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd