• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
基于选择占空比扰动的自适应MPPT算法
Adaptive MPPT Algorithm Based on Selecting Duty Cycle Disturbance
Received:April 08, 2019  Revised:April 08, 2019
DOI:10.19753/j.issn1001-1390.2020.16.008
中文关键词: PV发电  新型MPPT  自适应扰动  选择占空比
英文关键词: PV power generation, new MPPT, adaptive disturbance, selective duty cycle
基金项目:
Author NameAffiliationE-mail
HeZhiXin College of Electrical Engineering and Automation,Fuzhou University,Fuzhou 1416404564@qq.com 
LiShaoGang* College of Electrical Engineering and Automation,Fuzhou University,Fuzhou lsg993@126.com 
Hits: 1129
Download times: 550
中文摘要:
      由于外界环境因素的改变会导致功率-电压输出特性曲线发生改变,为了在光伏发电系统的最大功率跟踪过程中尽可能地提高MPP跟踪速度,缓解MPP点附近存在的振荡问题,该文章提出了一种基于选择占空比扰动的自适应MPPT算法,此方法是通过判断功率对电压的导数分界值来选择合适的占空比扰动值,较好地解决了快速性与稳定性的矛盾问题。最后通过搭建Matlab/Simulink模型验证该新型控制方法的优越性。
英文摘要:
      Due to changes in external environmental factors, Which will cause the power-voltage output characteristic curve changes. In order to improve the MPP tracking speed and mitigate the oscillation problem near the MPP point in the maximum power tracking process of the photovoltaic power generation system,An adaptive MPPT algorithm based on selecting the duty cycle disturbance is proposed. This method selects the appropriate duty cycle disturbance value by judging the derivative value of the power to voltage, which better solves the contradiction between rapidity and stability problem. Finally, the superiority of the new control method is verified by building Matlab/Simulink model.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd