• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
电压暂降时并网逆变器电流的VSG抑制技术研究
Research on VSG suppression technology of grid-connected inverter current under Grid Voltage Sag
Received:May 20, 2019  Revised:May 20, 2019
DOI:10.19753/j.issn1001-1390.2021.04.004
中文关键词: 虚拟同步发电机  并网控制  电压暂降  电流抑制
英文关键词: 
基金项目:
Author NameAffiliationE-mail
He Jiangtao College of Electrical Engineering and Information Technology,Sichuan University 961774412@qq.com 
Zhang Dairun* College of Electrical Engineering and Information Technology,Sichuan University drzhg@163.com 
Hits: 1412
Download times: 471
中文摘要:
      虚拟同步发电机(Virtual Synchronous Generator, VSG)控制技术能提升分布式电源对电网友好性。然而,电网电压暂降时,传统VSG控制会导致逆变器输出的电流过大,为此提出了一种VSG电流抑制控制方法。首先对电网电压暂降情况的检测进行分析与改进;在此基础上,利用VSG生成的指令电压进行参考电流计算,使VSG在各种电压暂降的情况下能实现对逆变器输出电流的幅值抑制。该方法结构简单,能实现不同故障情况下的电流控制。仿真结果验证了所提控制方法的正确性与有效性。
英文摘要:
      Virtual Synchronous Generator (VSG) control technology can improve the grid-friendliness of distributed power supplies. However, as the grid voltage drops, the traditional VSG control will cause the current output of the inverter to be too large. Therefore, a VSG current suppression control method is proposed. Firstly, the detection and improvement of the voltage sag of the power grid are analyzed and improved. On this basis, the reference voltage calculated by the VSG is used to calculate the reference current, so that the VSG can realize the output current amplitude suppression of the inverter under various voltage sag conditions. The method has a simple structure and can realize current control under different fault conditions. The simulation results verify the correctness and effectiveness of the proposed control method.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd