• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
基于暂态特征的配电线路自适应重合闸仿真研究
The research on adaptive auto-reclosure technique of distribution line based on the transient characteristic by simulation
Received:August 13, 2019  Revised:August 29, 2019
DOI:10.19753/j.issn1001-1390.2021.07.011
中文关键词: 配电线路  自适应重合闸  暂态特征
英文关键词: distribution line  adaptive Auto-reclosure  transient characteristic
基金项目:城市智能配电网保护与自愈控制关键技术
Author NameAffiliationE-mail
Zhang Zhihua Shanxi Electric Power Research Institute,Xi An zzhtsky123@163.com 
Liu Jian Shanxi Electric Power Research Institute,Xi An powersys@263.net 
Wu Shuilan* Xu ji Group corporation 273403203@qq.com 
Pang Jianwei Xu Ji Group corporation 247967645@qq.com 
XI Yake Xu Ji Group corporation 13849883693@139.com 
Zhang Jianyu Xu Ji Group corporation xjtc_zhangjianyu@126.com 
Hits: 1744
Download times: 406
中文摘要:
      当重合于永久性故障时断路器要连续切断两次短路电流,这会降低断路器的寿命和开断能力。文中提出在配电线路重合前投入预充好电的电容器的自适应重合闸方案,通过判别电容放电电压电流的暂态特征,来区别故障是永久性故障还是瞬时性故障,永久性故障时闭锁重合闸,瞬时性故障开放重合闸。仿真分析了各种工况时方案的可行性。
英文摘要:
      when permanent fault occurs, reclosure will fail, the circuit breaker must break short-current continuous twice, this condition will reduce the lifetime and breaking capacity of the circuit breaker. A scheme of Adaptive Auto-reclosure Technique of Distribution Line is put forward in order to distinguish the permanent fault or the transient fault, by distinguishing the transient characteristic of voltage and current of capacitor. when permanent fault occurs, it blocks reclosure; when transient fault occurs, it opens reclosure. The feasibility of the scheme under different conditions is analysed by the simulation.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd