• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
一种基于自适应下垂系数的虚拟惯性控制策略
A virtual inertia control strategy based on adaptive droop coefficient
Received:August 26, 2019  Revised:August 26, 2019
DOI:10.19753/j.issn1001-1390.2021.06.022
中文关键词: 直流微网  下垂控制  虚拟惯性
英文关键词: DC  grid, droop  control, virtual  inertia
基金项目:
Author NameAffiliationE-mail
Chai Yingbo Army Engineering University chaiyingbo@yeah.net 
Xie Pu* Army Engineering University xhpjhc2007@126.com 
Feng Gaohui Beijing Tsingsheng electrical research institute fgh1980fgh@163.com 
Hits: 1354
Download times: 468
中文摘要:
      由于直流微网中元件的特性与采用的控制方法,其往往呈现出惯性小的特点。当负载突变时,电压也会发生剧烈变化。针对此问题,文中提出了一种改进的下垂控制方法,并将电压变化率引入下垂系数中,控制了蓄电池的充放电动作,使得微网在原有储能元件的基础上进一步增大了惯性。详细讨论了算法中的一些细节问题,在MATLAB/Simulink中搭建包含了光伏电池及蓄电池的多端直流微网,并进行仿真验证。结果表明,所提算法能够减轻由于负载突变带来的电压剧烈变化,具有有效性与可行性。
英文摘要:
      As the results of the characteristics of the components and the control methods used in the DC grid, it presents the characteristics of small inertia. When the load mutates, the voltage also changes violently. In view of this problem, an improved droop control method is proposed in the paper, and the voltage change rate is introduced into the droop coefficient. The charging and discharging actions of the battery is controlled, so that the inertia of the grid further increases on the basis of the original energy storage elements. Some detailed problems in the algorithm are discussed in detail, and a multi-terminal PV-battery-based DC grid is established in MATLAB/Simulink, in which the simulation verification is carried out in. The results show that the algorithm proposed can alleviate the drastic change of voltage caused by load mutation, which is both effective and feasible.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd