文章摘要
基于运行误差估算的电能表准确性预计
Accuracy prediction of watt hour meter based on operation error estimation
Received:July 24, 2021  Revised:August 20, 2021
DOI:10.19753/j.issn1001-1390.2020.04.008
中文关键词: 运行误差  电能表  超阈值分布  准确性预计
英文关键词: Operation error  Electric energy meter  POT distribution  Accuracy prediction
基金项目:国家自然科学基金资助项目(61505028);江苏省高等学校自然科学研究面上项目(19KJD510007)
Author NameAffiliationE-mail
Cheng Lei* Department of Electronic and Communication Engineering,Suzhou Institute of Industrial Technology 8730657@qq.com 
Lu Lin Department of Electronic and Communication Engineering,Suzhou Institute of Industrial Technology 5456640@qq.com 
Bu Shupo Department of Electronic and Communication Engineering,Suzhou Institute of Industrial Technology 996391567@qq.com 
Hits: 1979
Download times: 406
中文摘要:
      电能表准确性取决于误差偏大数据的分布。本文根据台区内考核表与分表的量测数据估算分表运行误差,引入POT模型对分表运行误差的超阈值数据进行风险价值(VaR)度量。结果表明,本方法能在不同阈值与置信水平下预测电能表运行误差超限的概率,进而评估台区内电能表的准确性,为预防电能表超差造成的风险提供较为可靠的依据。
英文摘要:
      The accuracy of watt hour meter depends on the distribution of large error data. This paper estimates the operation error of sub meter according to the measurement data of assessment table and sub meter in the station area, and introduces the pot model to measure the value at risk (VaR) of the over threshold data of sub meter operation error. The results show that this method can predict the probability of the operation error exceeding the limit under different thresholds and confidence levels, and then evaluate the accuracy of the meters in the station area, which provides a more reliable basis for preventing the risk caused by the meter out of tolerance.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd